MODEL: 2004 MultiDiagnost Eleva
PA GANTRY - Motorized
Sid range, cm (in) - 95-120 (37.4-47.2)
Park capability - Yes
Depth, cm (in) - 90 (35.4)
Cranial-to-caudal angulation, deg - 45/45
Type - Floor C
Rao projection - 90
Counterbalanced - BodyGuard
Lao projection - 90
SUPPORT (EXTERNAL BEAM) - Floor
Power needed, VAC - 440 VAC, 60 Hz, 3-phase
X-ray generator - Power supplied by system
Type - Single plane
ROOM SPECIFICATIONS
Size, m (ft) - 3 x 2.6 (9.8 x 8.4)
NUMBER OF MONITORS (X-RAY TUBE) - 1
Monitor sizes (X-RAY TUBE) - 18"
IMAGE INTENSIFIER
Output, mm - 35/25
Contrast ratio - 22:1
Spatial resolution, center, lp/mm - 4/4.6/5.1/5.7/6
Input, cm (in) - (38/20/25/20/17 (15/12/10/8/6.7)
IMAGE STORAGE
512 x 512 - 240000 images
1024 x 1024 - 60000 images
X-RAY TUBE
Heat storage capacity, hu - 800000
Grid pulsed - Optional
Cooling method - Water
Heat dissipation rate, hu/min - 245000
Focal-spot size, mm - 0.6/0.8
Target angle, deg - 12
IMAGING CHARACTERISTICS
Acquisition, fps 512 x 512 - Up to 30
1024 x 1024 - Up to 8
ROTORS
0.5, 1, 2, 3, 4, 6
DIGITAL SYSTEM (TABLETOP)
Extended digital imaging
DICOM 3.0 COMPATIBLE - Yes
PATIENT TABLE CHARACTERISTICS
Size, cm(in) - 220 x 56 (87 x 22)
Patient capacity, kg (lb) - 185 (407.9)
Longitudinal (PATIENT TABLE CHARACTERISTICS)
Movement - Stationary
X-ray density - <1 mm Al
VIDEO INPUT/OUTPUT
Scan lines - 1,024/512
Camera type - CCD
Snr, db - 51 @ 300 nA
X-RAY GENERATOR
Power rating, kw @ 100 kvp - 80/100
Type - High-frequency
Fluoroscopic kv - 40-110
Fluoroscopic ma - 0.1-6
Radiographic timer - 1 msec-4 sec
Radiographic ma - 10-1,000
Radiographic kv - 40-150
X-ray tubes, maximum number - 2
Cine speed, fps - Optional 1-30
Pulsed fluoroscopy - Grid switched/pulsed
OPTIONAL FEATURES (PERFORMANCE)
Bolus chase (plus) and reconstruction, vascular processing, EasySpine, EasyLegs, ColonMap, OrthoAdvanced, gridcontrolled or pulsed fluoroscopy, rotational angio
INTENDED USE (TABLETOP)
Mixed RF and interventions
ADDITIONAL ATTRIBUTES (MICROMANIPULATORS)
90/90į table tilt; 20/20į table roll; optional grid-controlled fluoro.
Please do not hesitate to contact us if you have any questions regarding this item.
Hablamos español. Si necesitas asistencia en español, por favor no dude en comunicarse con nosotros.
Falamos portugués. Se você tiver qualquer dúvida ou precisar ajuda em portugués, por favor, não hesite em nos contactar.
Nous parlons le français. Si vous avez besoin d'aide en français, s'il vous plaît, n'hésitez pas à nous contacter pour toute question.
Parliamo italiano. Se avete qualsiasi domanda o bisogno di assistenza in italiano, per favore, non esitate a contattarci.